[108895620] There are multiple patients. All known information is detailed in the article. Event dates are multiple unknown dates between 2005 and 2012. This report is for an unknown synthes arch laminoplasty system and unknown synthes screws /unknown lot. Part and lot numbers are unknown; udi number is unknown. There are multiple unknown dates of implantation. It is unknown if or when devices were explanted. Complainant part is not expected to be returned for manufacturer review/investigation. There are multiple unknown concomitant therapy dates between 2005 and august 2011. Reporter postal code and phone number are unknown. Without a lot number the device history records review could not be completed. Product was not returned. Based on the information available, it has been determined that no corrective and/or preventative action is proposed. This complaint will be accounted for and monitored via post market surveillance activities. If additional information is made, the investigation will be updated as applicable. Device was used for treatment, not diagnosis. If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate. (b)(4).
Patient Sequence No: 1, Text Type: N, H10


[108895621] This report is being filed after the review of the following journal article: tung, kl. Et al (2015), single-door cervical laminoplasty using titanium miniplates alone, journal of orthopaedic surgery, vol. 23 no. 2, pages 174-179 ((b)(6)). The purpose of this study is to review the records for the outcome of 29 patients (20 men and 9 women) who underwent surgery between 2005 and 2012. Surgery included single-door cervical laminoplasty for myelopathy using titanium miniplates for treatment of cervical spondylotic myelopathy, ossification of the posterior longitudinal ligament and central cord system. Patient ages ranged 35 to 79 years. Prior to august 2011, 19 patients were implanted with a non-synthes 20-hole titanium miniplate; after august 2011, 10 patients were implanted with an unknown depuy synthes pre-contoured arch laminoplasty system. The mean follow-up was 4 years, ranging 2-9 years. Postoperatively, a soft neck collar was worn for 2 weeks with neck mobilization exercises permitted as pain improved. The authors did not specify if the complications experienced were involving patients implanted with non-synthes miniplates or the arch system. Therefore, all complications will be reported as follows for the arch system: hinge non-unions in 2 of the unplated laminae. Spring back closure occurred in 5 of the unplated laminae, with a mean of <3 mm loss of the initial expansion. Transient c5 palsy developed, presenting as shoulder abduction weakness in 2 patients. Delayed dural tear due to sharp spike at the edge of the opened c6 lamina in 1 patient. 2 screw pullouts (not associated with plate loosening). Concomitant devices: non-synthes 20-hole titanium miniplate (part number: unknown, lot number: unknown, quantity: unknown). This report is for an unknown synthes arch laminoplasty system and unknown synthes screws. This is report 1 of 1 for (b)(4).
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number8030965-2018-53824
MDR Report Key7525147
Date Received2018-05-18
Date of Report2018-04-25
Date Mfgr Received2018-04-25
Date Added to Maude2018-05-18
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMICHAEL COTE
Manufacturer Street1302 WRIGHTS LANE EAST
Manufacturer CityWEST CHESTER PA 19380
Manufacturer CountryUS
Manufacturer Postal19380
Manufacturer Phone6107195000
Single Use3
Previous Use Code3
Event Type3
Type of Report0

Device Details

Generic NameORTHOSIS, SPINE, PLATE, LAMINOPLASTY METAL
Product CodeNQW
Date Received2018-05-18
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device Eval'ed by Mfgr*
Device Sequence No1
Device Event Key0
ManufacturerOBERDORF SYNTHES PRODUKTIONS GMBH
Manufacturer AddressEIMATTSTRASSE 3 OBERDORF 4436 SZ 4436


Patients

Patient NumberTreatmentOutcomeDate
101. Required No Informationntervention 2018-05-18