NEUWAVE PR XT PROBE 20CM 15GA PR20XT

MAUDE Adverse Event Report

MAUDE data represents reports of adverse events involving medical devices. This maude entry was filed from a health professional report with the FDA on 2020-02-10 for NEUWAVE PR XT PROBE 20CM 15GA PR20XT manufactured by Neuwave Medical, Inc..

Event Text Entries

[182701674] Product complaint # (b)(4). Attempts are being made to obtain the following information.? To date no response has been provided. If further details are received at a later date a supplemental medwatch will be sent. Can you please clarify when the probe tip broke off the device (after the procedure, during use in the case, in the patient, etc. )? If the probe tip broke during the procedure, was the tip removed from the patient? Did removal cause any changes to the patient care? Was there any patient consequence or change in the post-operative care of the patient as a result of the event? Attempts have been made to retrieve the device. To date the device has not been returned. If the device or further details are received at a later date a supplemental medwatch will be sent.
Patient Sequence No: 1, Text Type: N, H10


[182701675] It was reported that the customer alerted the sales rep that they were getting repetitive "reflected power errors" on one of the two probes being used in a microwave ablation procedure. To mitigate, the sales rep recommended they make sure green portion of probe fully was embedded in tissue. Customer continued to get errors. Customer also mentioned that it appeared plastic sheathing was torn around distal cannula and tip appeared very charred. Customer reported the rp errors starting at about seven minutes into a ten minute cycle. Customer also noted temps reaching 170 c during cycle. Decision was made to discard probe and replace with a new probe. Final three minutes of cycle were completed without incident. The procedure was delayed by approximately ten minutes and was completed with no patient consequences reported. Upon examining the probe, the sales rep noticed that the distal 5 mm the tip of the probe was missing and alerted the customer.
Patient Sequence No: 1, Text Type: D, B5


MAUDE Entry Details

Report Number3008769756-2020-00003
MDR Report Key9687239
Report SourceHEALTH PROFESSIONAL
Date Received2020-02-10
Date of Report2020-03-06
Date of Event2020-01-21
Date Mfgr Received2020-03-06
Date Added to Maude2020-02-10
Event Key0
Report Source CodeManufacturer report
Manufacturer LinkY
Number of Patients in Event0
Adverse Event Flag3
Product Problem Flag3
Reprocessed and Reused Flag3
Health Professional3
Initial Report to FDA3
Report to FDA3
Event Location3
Manufacturer ContactMS. KARA DITTY-BOVARD
Manufacturer Street3529 ANDERSON ST
Manufacturer CityMADISON 53704
Manufacturer CountryUS
Manufacturer Postal53704
Manufacturer Phone6107428552
Manufacturer G1NEUWAVE MEDICAL, INC.
Manufacturer Street3529 ANDERSON ST
Manufacturer CityMADISON 53704
Manufacturer CountryUS
Manufacturer Postal Code53704
Single Use3
Previous Use Code3
Event Type3
Type of Report3

Device Details

Brand NameNEUWAVE PR XT PROBE 20CM 15GA
Generic NameSYSTEM, ABLATION, MICROWAVE AND ACCESSORIES
Product CodeNEY
Date Received2020-02-10
Model NumberPR20XT
Catalog NumberPR20XT
Lot NumberML19054346
OperatorHEALTH PROFESSIONAL
Device AvailabilityN
Device AgeDA
Device Eval'ed by MfgrR
Device Sequence No1
Device Event Key0
ManufacturerNEUWAVE MEDICAL, INC.
Manufacturer Address3529 ANDERSON ST MADISON 53704 US 53704


Patients

Patient NumberTreatmentOutcomeDate
10 2020-02-10

© 2024 FDA.report
This site is not affiliated with or endorsed by the FDA.